Stampa…

Hai cercato: Mass+Spectrometry


2 646  risultati sono stati trovati

SearchResultCount:"2646"

Sort Results

Visualizzazione a lista Nuova Visualizzazione

La tua valutazione

Codice catalogo: (40662-100MG)
Fornitore: Merck
Codice articolo fornitore: 40662-100MG
Codice articolo locale: SUPL40662-100MG
Descrizione: Simazine CRM may also be used as given below: Development and validation of an ultrasonic-assisted dispersive liquid-liquid microextraction (UA-DLLME) method for sample extraction followed by gas chromatography-mass spectrometry based determination of endocrine-disrupting herbicides in the river and seawater samples. Determination of triazine pesticide residues in samples of apples pears carrots potatoes tomatoes avocado cucumber spinach bananas and oranges by modified QuEChERS and solid-phase extraction (SPE) procedures followed by liquid chromatography-photodiode array (LC-DAD) analysis. Multi-residue analysis of 67 pesticides in olive oil olives and avocado samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) to evaluate various clean-up sorbents. Quantitation of 20 pesticides in eel and shrimp samples by a scheduled multiple reaction monitoring (sMRM) method and QuEChERS with EDTA for sample extraction and purification. Analysis of 35 micropollutants including pesticides in water samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) after their solid-phase extraction. Simultaneous quantification of 58 pharmaceuticals and personal care products (PPCPs) and pesticides in water samples by solvent-based de-emulsification dispersive liquid-liquid microextraction (SD-DLLME) combined with liquid chromatography-tandem mass spectrometry (LCMS/MS).
UOM: 1 * 100 mg


Codice catalogo: (56451-250MG)
Fornitore: Merck
Codice articolo fornitore: 56451-250MG
Codice articolo locale: SUPL56451-250MG
Descrizione: 1,5-Diaminonaphthalene is used as an effective matrix in the analysis of IgG protein using top-down and middle-down mass spectrometry with multiple fragmentation techniques such as electron transfer dissociation (ETD) and matrix-assisted laser desorption ionization in-source decay (MALDI-ISD) method.
UOM: 1 * 250 mg


Nuova trasparenza per i clienti europei

Hai notato la nostra nuova funzionalità che mostra la posizione a stock del prodotto a carrello?

Ulteriori informazioni

Visibilità della posizione a stock

Codice catalogo: (32666-10MG)
Fornitore: Merck
Codice articolo fornitore: 32666-10MG
Codice articolo locale: SUPL32666-10MG
Descrizione: Melamine-¹³C₃ may be used as an analytical standard for the determination of melamine in milk powder samples by liquid chromatography-electrospray ionisation-isotope dilution mass spectrometry (LC-ESI-IDMS).
UOM: 1 * 10 mg


Codice catalogo: (55901-25MG)
Fornitore: Merck
Codice articolo fornitore: 55901-25MG
Codice articolo locale: SUPL55901-25MG
Descrizione: Ecamsule (ECAM) has been used as a reference standard for observing the photo-stability and photo-sensitizing property of the ecamsule that forms a major ingredient in the production of sunscreen products by laser flash photolysis and steady-state HPLC coupled with mass spectrometry method.
UOM: 1 * 25 mg


Codice catalogo: (36372-50MG)
Fornitore: Merck
Codice articolo fornitore: 36372-50MG
Codice articolo locale: SUPL36372-50MG
Descrizione: Profenofos CRM may also be used as given below: Evaluation of 250 pesticide residues extracted by QuEChERS method from 103 processed fruit samples using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS. Gas chromatography-tandem mass spectrometry (GC-MS/MS) based analysis of 213 pesticide residues in soybean after their extraction by QuEChERS procedure. Detection of 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. Multi-residue analysis of 160 multiclass pesticides using ethyl acetate (EtAC)/n. hexane mixture for extraction from chamomile thyme and marjoram samples and their analysis by gas chromatography-tandem mass spectrometry (GC-MS/MS). Simultaneous determination of 34 pesticides in various environmental water samples by dispersive liquid-liquid microextraction (DLLME) technique in combination with gas chromatography-mass spectrometry(GC-MS/MS). Quantitation of 40 multi-class insecticides and fungicides in 81 apple samples by using gas- and liquid- chromatography-mass following a QuEChERS-based extraction.
UOM: 1 * 50 mg


Codice catalogo: (18996-50MG)
Fornitore: Merck
Codice articolo fornitore: 18996-50MG
Codice articolo locale: SUPL18996-50MG
Descrizione: Metrafenone CRM may also be used in the residue analysis of: 209 pesticides and persistent organic pollutants (POPs) extracted by QuEChERS-based procedure from fresh bovine and chicken liver samples using gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. 250 pesticide residues extracted by QuEChERS method from 103 processed fruit samples using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). 379 pesticides in human serum samples extracted by QuEChERS method using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Metrafenone in nine fresh vegetable samples using matrix solid-phase dispersion (MSPD) and HPLC-UV. Metrafenone in bitter gourd and soil samples using gas chromatography combined with an electron capture detector (GC-ECD).
UOM: 1 * 50 mg


Codice catalogo: (APOSPC7912-1G)
Fornitore: Apollo Scientific
Codice articolo fornitore: PC7912-1G
Codice articolo locale: APOSPC7912-1G
Descrizione: Mass Spectrometry standard
UOM: 1 * 1 g


Codice catalogo: (45634-50MG)
Fornitore: Merck
Codice articolo fornitore: 45634-50MG
Codice articolo locale: SUPL45634-50MG
Descrizione: Promecarb may be used as a reference standard for the determination of promecarb in water by solid-phase extraction and liquid chromatography coupled with ionspray mass spectrometry.
UOM: 1 * 50 mg


Fornitore: TCI
Descrizione: Tris(perfluorobutyl)amine >60.0% (by GC) for mass spectrometry

Codice catalogo: (19000-50MG)
Fornitore: Merck
Codice articolo fornitore: 19000-50MG
Codice articolo locale: SUPL19000-50MG
Descrizione: Monolinuron CRM may also be used as given below: Determination of 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. Extraction of 13 pesticides from four groundwater and three river water samples using silica-based MSU-1 mesoporous solid as a sorbent for their solid-phase extraction (SPE) followed by ultra-performance liquid chromatography-triple quadrupole-mass spectrometric (UHPLC- QqQ-MS/MS) determination. Development and validation of a UHPLC-diode array detection (DAD) method for simultaneous determination of urea and tebuthiuron herbicides in four fresh vegetable samples. Multi-residue analysis of 50 herbicides in 51 grain samples of soybean corn and wheat by ultra-performance liquid chromatography-electrospray ionisation-mass spectrometry (UPLC-ESI-MS). Extraction of 109 pesticide residues from different chemical classes from 345 tomato samples by modified QuEChERS method and their determination using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Simultaneous analysis of 238 pesticides and 78 veterinary drugs in 80 bovine milk samples using ultra-fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) and gas chromatography-tandem mass spectrometry (GC-MS/MS).
UOM: 1 * 50 mg


Codice catalogo: (TCIAP1061-5G)
Fornitore: TCI
Codice articolo fornitore: P1061-5G
Codice articolo locale: TCIAP1061-5G
Descrizione: Perfluorokerosene 50% in PFK low boiling, super-high boiling for mass spectrometry
UOM: 1 * 5 g


Fornitore: SIGMA ALDRICH MICROSCOPY
Descrizione: Tartrazine may be used as a reference standard in the determination of tartrazine in food samples using ion-pair liquid chromatography coupled with photodiode-array and electrospray mass spectrometry detector.
Codice catalogo: (906-0106)
Fornitore: VWR Collection
Codice articolo locale: SCSOK4628AA
Descrizione: Agilent OpenLab CDS is the next generation chromatography data system, designed for ease of use and productivity. OpenLab CDS offers the most comprehensive instrument control and data acquisition for Hitachi HPLC and amino acid analysers. In addition, it supports an expanded array of instrumentation from other vendors, for example Agilent LC, GC and LC/MS. Whether you like to control a single instrument or a huge network of different analytical instruments, OpenLab CDS grows with your needs.
UOM: 1 * 1 pezzi


Codice catalogo: (786-229)
Fornitore: G-Biosciences
Codice articolo fornitore: 786-229
Codice articolo locale: GENO786-229
Descrizione: Ultra pure proteomic grade water that is fully compatible with 2D electrophoresis and mass spectrometry analysis.
UOM: 1 * 1 L


Fornitore: Apollo Scientific
Descrizione: Mass spectrometry standard.

Fornitore: Apollo Scientific
Descrizione: Mass spectrometry standard.

Prezzo a richiesta
La disponibilità per questo articolo è limitata, ma potrebbe essere disponibile in un magazzino vicino a voi. Si prega di assicurarsi che si è effettuato l'accesso al sito, in modo che ledisponibilità possano essere visualizzati. Se il call è ancora visualizzato e hai bisogno di assistenza, si prega di telefonare a 1-800-932 - 5000.
La disponibilità per questo articolo è limitata, ma potrebbe essere disponibile in un magazzino vicino a voi. Si prega di assicurarsi che si è effettuato l'accesso al sito, in modo che ledisponibilità possano essere visualizzati. Se il call è ancora visualizzato e hai bisogno di assistenza, si prega di telefonare a 1-800-932 - 5000.
Puoi ordinare questo prodotto. Se necessario, ti contatteremo per richiedere licenza, autorizzazione o dichiarazione d'uso per procedere con la fornitura.
Puoi ordinare questo prodotto. Se necessario, ti contatteremo per richiedere licenza, autorizzazione o dichiarazione d'uso per procedere con la fornitura.
Questo prodotto è stato bloccato dalla vostra organizzazione. Si prega di contattare il vostro responsabile acquisti per ulteriori informazioni.
Il prodotto originale non è più disponibile. L'articolo suggerito è disponibile
Il prodotto marcato con questo simbolo non è più disponibile o vendibile fino ad esaurimento scorte. Alternative possono essere disponibili utilizzando il numero di catalogo VWR. Per maggiori informazioni può contattare il nostro customer service al 023320311 o inviando una email all'indirizzo ebusiness.italy@avantorsciences.com
17 - 32 of 2 646
no targeter for Bottom