Stampa…

Conical centrifuge tubes with real-time temperature signaling, ViewPoint™

Fornitore: LABCON
3005-840-000-9 3210-320-008-9 3210-325-008-9 3210-335-008-9 3220-320-008-9 3220-325-008-9 3220-335-008-9
3005-840-000-9EA 391 EUR
3005-840-000-9 3210-320-008-9 3210-325-008-9 3210-335-008-9 3220-320-008-9 3220-325-008-9 3220-335-008-9
Conical centrifuge tubes with real-time temperature signaling, ViewPoint™
Tubi Tubi per centrifuga
ViewPoint™ tubes are designed to help track the real-time temperature of samples when doing bench work or transferring samples to storage. ViewPoint™ centrifuge tubes visibly signal the temperature of the tube and contents, shifting to dark blue when the temperature of tube contents is below 0 °C.

  • Keep control over work and improve processing times
  • ATP-, RNase/DNase-, and endotoxin-free (non-pyrogenic)
  • Sperm Motility Assay (SMA), Mouse Embryo Assay (MEA) validated safe for cell culture
  • Validated Sterilization (ISO 11137) for use in Research and Medical labs
  • Polypropylene USP Class VI resin, free of DiHEMDA, oleamide, and BPA
  • Freezable to –80 °C, and autoclavable
  • 15 and 50 ml tubes’ caps include integral molded elastomeric seal

ViewPoint™ tubes transition from clear to blue when exposed to cold temperatures. This multi-step and reversible thermochromic transition offers real-time temperature signaling to indicate fluctuations above and below 4 °C. At 5 °C and above ViewPoint™ tubes are clear and transparent. At 4 °C ViewPoint™ tubes transition to light blue and become slightly opaque. At 0 °C ViewPoint™ tubes reach their full progressive transition to dark blue, are completely opaque, and provide protection from Ultraviolet (UV) light.

A large number of protocols require chilled cells and/or chilled solvents. In these protocols samples and solutions are chilled for 30 minutes, 3 hours, or overnight. ViewPoint™ signals that a sample is chilled to 0 to 4 °C. Efficient chilling reduces incubation time, saving researchers time in a busy workflow. It is critical to reduce the formation of ice crystals when working with aqueous samples. Ice crystals begin to form at 0 to 4°C and damage cells. ViewPoint™ tubes begin transitioning from clear to light blue at 4 °C with full dark blue signaling at 0 °C. Real-time temperature signaling alerts the researcher to potentially harmful ice crystal formation and enables the maintenance of the desired temperature throughout experimentation.

Confezione: IntegraPack® includes 10 tubes per bag, 5 bags per pack. Reusable polypropylene rack includes 25 tubes per rack, 2 racks per pack, 6 packs per case.
Visualizza i codici

Learn more

About VWR

Avantor is a vertically integrated, global supplier of discovery-to-delivery solutions for...

Informazioni About VWR