Stampa…

Citometri a flusso con piattaforma CytoFLEX

Fornitore: Beckman Coulter
B53010 B53011 B53012 B53016 B53000 B53001 B53002 B53003 B53004 B53005 B53006 B53007 B53008 B53009 B53013 B53014 B53018 B53037 B96622 C02944 B75408 B75811 B75812 B78557 B78558 B78559 B78560 C02945 C02946 B78561 B96618 B96619 B96620 B96621 C02948 C00445 C00446 C02949 C11183 C11184 C01158 C01159 C01160 C01161 C02947 C11185 C11186
BECMB53010EA 0 EUR
BECMB53010 BECMB53011 BECMB53012 BECMB53016 BECMB53000 BECMB53001 BECMB53002 BECMB53003 BECMB53004 BECMB53005 BECMB53006 BECMB53007 BECMB53008 BECMB53009 BECMB53013 BECMB53014 BECMB53018 BECMB53037 BECMB96622 BECMC02944 BECMB75408 BECMB75811 BECMB75812 BECMB78557 BECMB78558 BECMB78559 BECMB78560 BECMC02945 BECMC02946 BECMB78561 BECMB96618 BECMB96619 BECMB96620 BECMB96621 BECMC02948 BECMC00445 BECMC00446 BECMC02949 BECMC11183 BECMC11184 BECMC01158 BECMC01159 BECMC01160 BECMC01161 BECMC02947 BECMC11185 BECMC11186
Citometri a flusso con piattaforma CytoFLEX
Conta cellule Citometri a flusso
Il citometro a flusso con piattaforma CytoFLEX è un sistema rivoluzionario dotato di sensibilità
ed emissioni ottimali, riduce al minimo la perdita di luce e aumenta al massimo la sensibilità.

  • Eccellente sensibilità (80 nm) che consente l'analisi delle nano particelle comprese le vescicole extracellulari, virus e altro ancora
  • Ampio set di filtri di passaggio a banda riposizionabili
  • Flessibilità per l'aggiornamento aggiungendo parametri supplementari
  • Software intuitivo per semplificare le analisi multicolore

The CytoFLEX platform is divided into several versions across three models. An instrument is defined by the lasers included. Each instrument is offered in a number of configurations, determined by the number of activated channels from each laser. Choose the configuration and number of parameters needed immediately, and activate additional parameters as the needs of the laboratory change in the future. Each instrument includes the full complement of repositionable band pass filters. Move filters to the activated channels based upon the wavelengths to be detected. Additional non standard band pass filters are available for even more assay flexibility.

CytoFLEX models bring up to three lasers instrument providing up to 13 fluorescent channels to accommodate most basic flow cytometry assay needs.
- Violet-Blue-Red (VB-R) Series, fully activated as few as one laser and four colours, activate additional colours and upgrade later, up to three lasers and 13 colours
- Includes 15 band pass filters

CytoFLEX S models bring up to four laser instruments to the research community expanding the fluorochrome palette for special applications. Four different series are available.
- The four series are: Violet-Blue-Yellow Green-Red (V-B-Y-R), Near UV-Violet-Blue-Red (N-V-BR), Near UV-Violet-Blue-Yellow Green (N-V-B-Y), Violet-Blue-Red-IR (V-BR-I)
- Activate as few as two lasers and four colours and upgrade later within the series, up to four lasers and 13 colours
- Includes 15 band pass filters depending on the chosen series

CytoFLEX LX models bring up to six laser instruments to the research community providing up to 21 fluorescent channels. Two different series are available, depending on choice of UV or near UV laser.
- Two series are available depending on your choice of UV or near-UV: UV-Violet-Blue-Yellow Green-Red-IR (UV-B-Y-R-I) and Near UV-Violet-Blue-Yellow Green-Red-IR (NV-B-Y-R-I)
- Activate as few as four lasers and 14 colour parameters or fully activate all six lasers for 21 colour parameters
- Includes 23 band pass filters depending on the chosen series

Additional specifications:
- Nominal acquisition rate: 30000 events per second with all configured parameters
- Signal processing: Fully digital system with seven decade data display
- Sample flow rates: Fixed flow rates: 10, 30 and 60 μl/min and custom flow rate Ccntrol mode from 10 to 240 μl/min in 1 μl increments
- Absolute counting: Gravimetric calibration for absolute counts within CytExpert software
- Software: Three different installation modes are available depending on the level of security required: Default Mode with no user login, User Management Mode and - Electronic Records Management Mode, which provides tools that facilitate compliance with 21 CFR Part 11
- Automation: An API (Application Programming Interface) is available for automation integration
- Scatter performance is optimised for resolving human lymphocytes, monocytes and granulocytes as well as nanoparticles
- Optional plate loader available to support 96-well flat and deep well plates (45,5 mm height max, 5,8 mm well bottom diameter minimum)