Stampa…

Hai cercato: Polarimetri

Used with optically active substances, polarimeters measure the angle of rotation caused by passing linear polarized light through the substances. Depending on the optically active compounds, the unidirectional light waves rotate the plane of polarization in different directions. Digitally displayed values for angle of rotation and international sugar scale measurements are large and easy to read. Quartz plates are used in calibration  kits to test and adjust polarimeters. A push-button interface allows user to easily modify operation rate, making the polarimeters versatile enough for use in a variety of industries including pharmaceutical industries.

Used with optically active substances, polarimeters measure the angle of rotation caused by passing linear polarized light through the substances. Depending on the optically active compounds, the unidirectional light waves rotate the plane of polarization in different directions. Digitally displayed values for angle of rotation and international sugar scale measurements are large and easy to read. Quartz plates are used in calibration kits to test and adjust polarimeters. A push-button interface allows user to easily modify operation rate, making the polarimeters versatile enough for use in a variety of industries including pharmaceutical industries.


46  risultati sono stati trovati

Sort Results

Visualizzazione a lista Nuova Visualizzazione
SearchResultCount:"46"
Descrizione: Polarimetro digitale, Polarimetro a singola lunghezza d'onda con 3 tag RFID, UK/EU-plugs, Scala angolare - range: −355…+355 °A, Scala angolare - accuratezza: ±0,01 °A, Scala dello zucchero - range (°Z): −225…+225 °Z, Range di densità ottica (OD): 0,0…3,0
Codice catalogo: BELL37-50
UOM: 1 * 1 pezzi
Codice articolo fornitore: 37-50
Codice articolo locale: BELL37-50
Fornitore: BELLINGHAM STANLEY


Descrizione: Digital polarimeter, Single wavelength polarimeter with three RFID tags, UK/EU-plugs, Scala angolare - range: −355…+355 °A, Scala angolare - accuratezza: ±0,010 °A, Scala dello zucchero - range (°Z): −225…+225 °Z, Scala dello zucchero - Accuratezza (°Z): ± 0,030 °Z, Range di densità ottica (OD): 0,0…3,0
Codice catalogo: BELL37-30
UOM: 1 * 1 pezzi
Codice articolo fornitore: 37-30
Codice articolo locale: BELL37-30
Fornitore: BELLINGHAM STANLEY


Descrizione: Digital polarimeter, Single wavelength polarimeter, UK/EU-plugs, Scala angolare - range: ±89 °A (−355…+355 nm <i>via Method selection</i>), Scala angolare - accuratezza: ±0,003 °A (> 546 nm) ; ±0,005 °A (< 546 nm), Scala dello zucchero - range (°Z): −225…+225 °Z, Range di densità ottica (OD): 0,0…3,0, Lunghezza d'onda: 589 nm
Codice catalogo: BELL37-61
UOM: 1 * 1 pezzi
Codice articolo fornitore: 37-61
Codice articolo locale: BELL37-61
Fornitore: BELLINGHAM STANLEY


Descrizione: Digital polarimeter, Multi-wavelength polarimeter, UK/EU-plugs, Scala angolare - range: ±89 °A (−355…+355 nm <i>via Method selection</i>), Scala angolare - accuratezza: ±0,003 °A (> 546 nm) ; ±0,005 °A (< 546 nm), Scala dello zucchero - range (°Z): −225…+225 °Z, Range di densità ottica (OD): 0,0…3,0, Lunghezza d'onda: 365, 405, 436, 546, 589 nm
Codice catalogo: BELL37-65
UOM: 1 * 1 pezzi
Codice articolo fornitore: 37-65
Codice articolo locale: BELL37-65
Fornitore: BELLINGHAM STANLEY


Descrizione: Digital polarimeter, Multi-wavelength polarimeter, UK/EU-plugs, Scala angolare - range: ±89 °A (−355…+355 nm <i>via Method selection</i>), Scala angolare - accuratezza: ±0,003 °A (> 546 nm) ; ±0,005 °A (< 546 nm), Scala dello zucchero - range (°Z): −225…+225 °Z, Range di densità ottica (OD): 0,0…3,0, Lunghezza d'onda: 405, 436, 546, 589 nm
Codice catalogo: BELL37-64
UOM: 1 * 1 pezzi
Codice articolo fornitore: 37-64
Codice articolo locale: BELL37-64
Fornitore: BELLINGHAM STANLEY


Descrizione: Digital polarimeter, Dual wavelength polarimeter, UK/EU-plugs, Scala angolare - range: ±89 °A (−355…+355 nm <i>via Method selection</i>), Scala angolare - accuratezza: ±0,003 °A (> 546 nm) ; ±0,005 °A (< 546 nm), Scala dello zucchero - range (°Z): −225…+225 °Z, Range di densità ottica (OD): 0,0…3,0, Lunghezza d'onda: 546, 589 nm
Codice catalogo: BELL37-62
UOM: 1 * 1 pezzi
Codice articolo fornitore: 37-62
Codice articolo locale: BELL37-62
Fornitore: BELLINGHAM STANLEY


Descrizione: Digital polarimeter, Multi-wavelength polarimeter, UK/EU-plugs, Scala angolare - range: ±89 °A (−355…+355 nm <i>via Method selection</i>), Scala angolare - accuratezza: ±0,003 °A (> 546 nm) ; ±0,005 °A (< 546 nm), Scala dello zucchero - range (°Z): −225…+225 °Z, Range di densità ottica (OD): 0,0…3,0, Lunghezza d'onda: 325, 365, 405, 436, 546, 589 nm
Codice catalogo: BELL37-66
UOM: 1 * 1 pezzi
Codice articolo fornitore: 37-66
Codice articolo locale: BELL37-66
Fornitore: BELLINGHAM STANLEY


Descrizione: Digital polarimeter, Dual wavelength polarimeter, UK/EU-plugs, Scala angolare - range: ±89 °A (−355…+355 nm <i>via Method selection</i>), Scala angolare - accuratezza: ±0,003 °A (> 546 nm) ; ±0,005 °A (< 546 nm), Scala dello zucchero - range (°Z): −225…+225 °Z, Range di densità ottica (OD): 0,0…3,0, Lunghezza d'onda: 365, 589 nm
Codice catalogo: BELL37-63
UOM: 1 * 1 pezzi
Codice articolo fornitore: 37-63
Codice articolo locale: BELL37-63
Fornitore: BELLINGHAM STANLEY


Descrizione: Polarimetro, Tappi in metallo per tubi di vetro, Ø 15,5 mm
Codice catalogo: 635-1004
UOM: 1 * 2 pezzi
Codice articolo fornitore: 35-20
Codice articolo locale: BELL35-20
Fornitore: BELLINGHAM STANLEY


Descrizione: Polarimetro, Tenute in gomma per tappi in metallo per tubi e strumento per montaggio, Ø 15,5 mm
Codice catalogo: 635-1005
UOM: 1 * 12 pezzi
Codice articolo fornitore: 35-21
Codice articolo locale: BELL35-21
Fornitore: BELLINGHAM STANLEY


Descrizione: Polarimetro, Tubo polarimetrico in acciaio inox, XPC100, 100 mm
Codice catalogo: BELL35-90
UOM: 1 * 1 pezzi
Codice articolo fornitore: 35-90
Codice articolo locale: BELL35-90
Fornitore: BELLINGHAM STANLEY


Descrizione: Polarimetro, Tubo di vetro del campione con la lampadina, 200 mm
Codice catalogo: 635-0025
UOM: 1 * 1 pezzi
Codice articolo fornitore: 35-30
Codice articolo locale: BELL35-30
Fornitore: BELLINGHAM STANLEY


Descrizione: Polarimetro, Metal end caps
Codice catalogo: BELL37-543
UOM: 1 * 2 pezzi
Codice articolo fornitore: 37-543
Codice articolo locale: BELL37-543
Fornitore: BELLINGHAM STANLEY


Descrizione: Polarimetro, Centre filling glass tube with cup shaped filler and metal ends, 200 mm
Codice catalogo: BELL35-18
UOM: 1 * 1 pezzi
Codice articolo fornitore: 35-18
Codice articolo locale: BELL35-18
Fornitore: BELLINGHAM STANLEY


Descrizione: Polarimetro, Centre filling glass tube with cup shaped filler and metal ends, 100 mm
Codice catalogo: BELL35-17
UOM: 1 * 1 pezzi
Codice articolo fornitore: 35-17
Codice articolo locale: BELL35-17
Fornitore: BELLINGHAM STANLEY


Descrizione: Polarimetro, Vetri bassi della copertura di sforzo per i tubi di vetro
Codice catalogo: 635-0289
UOM: 1 * 12 pezzi
Codice articolo fornitore: 35-60
Codice articolo locale: BELL35-60
Fornitore: BELLINGHAM STANLEY


1 - 16 of 46